No products in the cart.

Yes

Technochrom FVIII:C 2G CAL

Freeze-dried
Technoclone
Packaging options
4-5344104Kit 6 x 1 mL
The Technochrom FVIII:C 2G CAL is a set of calibrators for calibration of Factor VIII activity in the Technochrom FVIII:C 2G assay.
Description of the Technochrom FVIII:C 2G CAL
Technochrom FVIII:C 2G CAL is a set of calibrators designed for the precise calibration of Factor VIII activity (FVIII:C) in the Technochrom FVIII:C 2G chromogenic assay. Formulated with lyophilized human citrated plasma, each calibrator is stabilized to ensure reliable traceability and high reproducibility. Exclusively used with the Technochrom FVIII:C 2G assay, this calibrator set enables the generation of a multi-level calibration curve for the measurement of Factor VIII activity in human plasma.

Contents of Technochrom FVIII:C 2G CAL

CAL 1 – Calibrator 1: 1 vial containing 1 mL of lyophilized human citrated plasma and stabilizers, with an approximate Factor VIII (FVIII) activity of 160%.

CAL 2 – Calibrator 2: 1 vial containing 1 mL of lyophilized human citrated plasma and stabilizers, with an approximate Factor VIII (FVIII) activity of 80%.

CAL 3 – Calibrator 3: 1 vial containing 1 mL of lyophilized human citrated plasma and stabilizers, with an approximate Factor VIII (FVIII) activity of 40%.

CAL 4 – Calibrator 4: 1 vial containing 1 mL of lyophilized human citrated plasma and stabilizers, with an approximate Factor VIII (FVIII) activity of 20%.

CAL 5 – Calibrator 5: 1 vial containing 1 mL of lyophilized human citrated plasma and stabilizers, with an approximate Factor VIII (FVIII) activity of 10%.

CAL 6 – Calibrator 6: 1 vial containing 1 mL of lyophilized human citrated plasma and stabilizers, with an approximate Factor VIII (FVIII) activity of 0%.

Additional Information ;

  • Base material: Human citrated plasma pooled from selected healthy donors.
  • Modified by: Dilution in FVIII-deficient plasma or supplementation with purified Factor VIII.
  • Stabilized with: HEPES buffer solution.
  • Presentation: Lyophilized preparation for enhanced stability and long-term storage.
Key Benefits
  • Full calibration range: 6 calibrators from 0% to ~160% FVIII:C activity.
  • High traceability: Standardized against WHO reference material for Factor VIII.
  • Ready-to-use format after reconstitution for consistent and reliable performance.
  • Optimized for automation: Fully compatible with Ceveron® 100 analyzers, with barcode-based data input.
  • Validated human plasma: Pooled, citrated human plasma tested negative for HIV, HBV, and HCV.
  • Strict manufacturing standards: Designed for accuracy, precision, and reproducibility in FVIII:C assays.
CEIVDstockage_2_8C4h_TAdistributeur
product sheet
Price list, safety data sheets and notices are accessible to our registered customers.